Auxiliary Systems Logo

Auxiliary Systems Evaporator Support Form

Tuesday, September 26, 2017

Auxiliary Systems Logo

Auxiliary Systems Is An Authorized Original Equipment Manufacturer (OEM) For:


International Association of Drilling Contractors
IADC Member

Underwriters Laboratories Member
UL Member

VOW Coalition Member
Virginia Offshore Wind Coalition Member


And An Authorized Sales Representative For:
URC

AC Pro Whipp & Bourne Solid State Trip Units
Sales & Installation

ACB-1600 HR 3P, 500 VAC, 60 HZ, Circuit Breaker Solid State Trip Unit
ACB-2000 HR 3P, 500 VAC, 60 HZ, Circuit Breaker Solid State Trip Unit
ACB-3200 HR 3P, 500 VAC, 60 HZ, Circuit Breaker Solid State Trip Unit
ACB-4000 HR 3P, 500 VAC, 60 HZ, Circuit Breaker Solid State Trip Unit



TC Wilson Logo

Tube Equipment & Tools for: Beading, Belling, Expanders, Extractors, Flaring, Inserts, Knock Out, Packing, Packing Removal, Plugs, Pullers, & Rolling Motors

Aqua-Chem Evaporator TAO Class Ships
Auxiliary Systems Evaporator Marine Repair Support Form


Ship Information
Ships' Name Hull Number

Contact Information
Name Rank
Telephone Number Extension Number
Email Address
Work Center

Equipment Manufacturer Information
Serial Number Model Number
Technical Manual Number

Brief Descprition Of Problem

Preliminary Information
Is the boiler steam plant pressure steady and not fluctuating for the supplied steam to this evaporator?
Is your air ejector condenser vent line steadily venting steam to the atmosphere? A slight "puffing" of steam is normal.
Are any the evaporator systems high or flooded, such as Flash Chambers, Distillate Sight Glasses, or Feed Water Heater Sight Glasses?
Are any of the pump mechanical seals leaking fluid or pulling a suction from the atmosphere, such as Distillate Pump, Condensate Pump, or/and Brine Pump?
Pumps that have packing glands and packing strands, in lieu of mechanical seals, are designed for a slight leak off rate of 20 to 40 drops per minute.
Is pump leak off rate 20 to 40 drops per minute?
Is the packing gland dead ended to the pump casing body?
Is the packing gland allowing air to be sucked back into the pump body cavity?
When was the last time the Feed Water Heater Tubes were cleaned?

Pressure Gauge Readings
(P1)
Evaporator Shell
(P2)
Distillate Pump
Discharge
(P3)
Distillate Cooler
Distillate Out
(P4)
Eductor
Motive Water


Temperature Gauge Readings
(T1)
Heating Water In
(T2)
Heating Water Out
(T3)
Cooling Water In
(T4)
Cooling Water Out

(T5)
Evaporator Shell
(T6)
Distillate Pump Discharge
(T7)
Residence Tank
(T8)
Distillate Out

Salinity Cell Readings
(S1)
Distillate Cooler Inlet
(S2)
Distillate Cooler Outlet

Water Meters Readings
Feed Flow Rate Meter Distillate Capacity Meter

   